Connecting the wires
The CC-16 zone controller uses a standard 6-wire Eurostyle terminal block for power and
network connections.
1. Connect the network cable to the RS-485 A/B pins on the ESP-88. Note which wire is
connected to A and B.
2. Connect the network cable to the CC-16 terminal blocks. Ensure the wire connected to “A”
on the ESP-88 is the same one connected to “A” on the controllers and that the “B-wire” is
connected to “B” on the controllers. Connect Shield to the RS-485 cable shield if necessary.
3. Connect the power supply to the Ground and Vin+ terminals on the controllers.
Wiring Example
Wiring